Certificates of Product Ratings
Outstanding Features
Integrated base pan & air outlet assembly (for 9K12K18K structure)

Easier Installation and maintenance.

Easier Installation and maintenance.
Ionizer (optional)

Release negative ions, eliminate odor, dust, smoke and pollen particles to give you fresh and healthy air.

Release negative ions, eliminate odor, dust, smoke and pollen particles to give you fresh and healthy air.
2-way draining connection (optional)

Both left and right sides of indoor unit are possible for drainage hose connection, easy for installation.

Both left and right sides of indoor unit are possible for drainage hose connection, easy for installation.
Refrigerant leakage detect

When system has leakage or compressor overload, the display board will show
“EC” to alarm users which can better prevent the compressor being damaged.

When system has leakage or compressor overload, the display board will show
“EC” to alarm users which can better prevent the compressor being damaged.
Louver position memory function

When you start the unit next time, the angle of horizontal louver will automatically
move to the same position as you set last time.

When you start the unit next time, the angle of horizontal louver will automatically
move to the same position as you set last time.
Anti-mildew function (Optional)

When turns off the unit on COOL, DRY, AUTO (Cool) mode, the air conditioner will continue operating for about 10 minutes (depending on models) at LOW fan speed. This will help to dry up the condensed water inside the evaporator, and prevent the breeding of mildew.
Under Anti-mildew operation, do not restart the air conditioner until the unit is completely off.

When turns off the unit on COOL, DRY, AUTO (Cool) mode, the air conditioner will continue operating for about 10 minutes (depending on models) at LOW fan speed. This will help to dry up the condensed water inside the evaporator, and prevent the breeding of mildew.
Under Anti-mildew operation, do not restart the air conditioner until the unit is completely off.
Self cleaning (depend on remote control)

For heat pump models, after running in cooling or drying mode, if the user press “Self Clean” button on remote controller, firstly, indoor unit runs in fan only mode for a while, then low heat operation and finally runs in fan only again. This function can keep the inside of indoor unit dry and prevent breeding of mold.
Advantage for end-user: This function can keep the inside of indoor unit dry and prevent breeding of mildew, supply clean and healthy air to people.

For heat pump models, after running in cooling or drying mode, if the user press “Self Clean” button on remote controller, firstly, indoor unit runs in fan only mode for a while, then low heat operation and finally runs in fan only again. This function can keep the inside of indoor unit dry and prevent breeding of mold.
Advantage for end-user: This function can keep the inside of indoor unit dry and prevent breeding of mildew, supply clean and healthy air to people.
Follow me (depend on remote control)

The advantage for end-user: With this function, the room temperature sensor built in remote controller is activated and replaces the one in indoor unit. Then the air conditioner will regulate the room temperature based on the temperature around the remote controller, just like the air conditioner is following the user.
Pressing the “Follow me” button on remote controller to active this function. Then the remote controller will send PCB the signal every three minutes. If the PCB doesn’t receive the signal for 7 minutes or pressing “Follow me” button again, the follow me function will terminate.

The advantage for end-user: With this function, the room temperature sensor built in remote controller is activated and replaces the one in indoor unit. Then the air conditioner will regulate the room temperature based on the temperature around the remote controller, just like the air conditioner is following the user.
Pressing the “Follow me” button on remote controller to active this function. Then the remote controller will send PCB the signal every three minutes. If the PCB doesn’t receive the signal for 7 minutes or pressing “Follow me” button again, the follow me function will terminate.
Standard Features
“GOLD FIN” of indoor unit and outdoor unit
Effectively prevents bacteria propagation and improves heat transfer efficiency. The unique anti-corrosive golden coating on the condenser can withstand the salty air, rain and other corrosive factors. The Golden hydrophilic condenser can improve the heating efficiency by accelerating the defrosting process.

Auto Restart Function

Cold catalyst filter

Turbo Mode

Sleep Mode

Timer

Temp. Compensation

Follow me

Self cleaning
Optional Features

8°C heating

Low ambient cooling

Optional filter
Download manual
Model | OS-09HP115V2TG | |
System Type | Heat Pump | |
Power Supply | 115V / 60Hz | |
Rated Current Cooling | Amps | 8.9 |
Rated Current Heating | Amps | 7.9 |
System Performance | ||
Cooling Capacity (Min-Max) | Btu/h | 9,000 |
Heating Capacity (Min-Max) | Btu/h | 9,000 |
SEER/EER | 15 / 9.0 | |
HSPF/COP | 8.2 / 3.2 | |
Indoor Unit | ||
Air Flow | CFM | 480/420/320 |
Sound Pressure Level – T/H/M/L | dB (A) | 39/35/29 |
Unit Dimension (WxHxD) | inches | 26.8 x 10.1 x 7.0 |
Package Dimension (WxHxD) | inches | 29.3 x 13.0 x 10.1 |
Net / Gross Weight | lb | 15 / 18 |
Outdoor Unit | ||
Compressor Type | DC Inverter-driven rotary | |
Sound Pressure Level | dB (A) | 56 |
Unit Dimension (WxHxD) | inches | 26.0 x 21.3 x 10.4 |
Package Dimension (WxHxD) | inches | 31.3 x 24.4 x 14.0 |
Net / Gross Weight | lb | 64 / 71 |
Refrigerant / Charge | oz. | R410A / 31.8 |
Line Set Size (Liquid – Suction) | inches | 1/4" – 3/8" |
Pre-Charge | Feet | 25 |
Max. Line Run | Feet | 82 |
Max. Elevation | Feet | 33 |
MCA | Amps | 15 |
MOCP | Amps | 25 |
Wire Size / # Wires | AWG16 / 4 |
Model | OS-12HP115V2TG | |
System Type | Heat Pump | |
Power Supply | 115V / 60Hz | |
Rated Current Cooling | Amps | 11.9 |
Rated Current Heating | Amps | 11.7 |
System Performance | ||
Cooling Capacity (Min-Max) | Btu/h | 12,000 |
Heating Capacity (Min-Max) | Btu/h | 12,000 |
SEER/EER | 15 / 8.7 | |
HSPF/COP | 8.2 / 3.2 | |
Indoor Unit | ||
Air Flow | CFM | 580/500/400 |
Sound Pressure Level – T/H/M/L | dB (A) | 39/35/29 |
Unit Dimension (WxHxD) | inches | 30.3 x 10.1 x 7.4 |
Package Dimension (WxHxD) | inches | 32.9 x 13.0 x 10.4 |
Net / Gross Weight | lb | 17 / 21 |
Outdoor Unit | ||
Compressor Type | DC Inverter-driven rotary | |
Sound Pressure Level | dB (A) | 55 |
Unit Dimension (WxHxD) | inches | 26.0 x 21.3 x 10.4 |
Package Dimension (WxHxD) | inches | 31.3 x 24.4 x 14.0 |
Net / Gross Weight | lb | 64 / 71 |
Refrigerant / Charge | oz. | R410A / 33.6 |
Line Set Size (Liquid – Suction) | inches | 1/4" – 1/2" |
Pre-Charge | Feet | 25 |
Max. Line Run | Feet | 82 |
Max. Elevation | Feet | 33 |
MCA | Amps | 20 |
MOCP | Amps | 30 |
Wire Size / # Wires | AWG16 / 4 |
Model | OS-09HP220V2TG | |
System Type | Heat Pump | |
Power Supply | 208-230V / 60Hz | |
Rated Current Cooling | Amps | 3.9 |
Rated Current Heating | Amps | 4.0 |
System Performance | ||
Cooling Capacity (Min-Max) | Btu/h | 9,000 |
Heating Capacity (Min-Max) | Btu/h | 9,000 |
SEER/EER | 15 / 10.0 | |
HSPF/COP | 8.2 / 2.9 | |
Indoor Unit | ||
Air Flow | CFM | 530/430/390 |
Sound Pressure Level – T/H/M/L | dB (A) | 40/33/28 |
Unit Dimension (WxHxD) | inches | 26.8 x 10.1 x 7.0 |
Package Dimension (WxHxD) | inches | 29.3 x 13.0 x 10.1 |
Net / Gross Weight | lb | 14 / 17 |
Outdoor Unit | ||
Compressor Type | DC Inverter-driven rotary | |
Sound Pressure Level | dB (A) | 56 |
Unit Dimension (WxHxD) | inches | 27.6 x 21.3 x 9.5 |
Package Dimension (WxHxD) | inches | 32.1 x 22.8 x 12.8 |
Net / Gross Weight | lb | 58 / 63 |
Refrigerant / Charge | oz. | R410A / 24.0 |
Line Set Size (Liquid – Suction) | inches | 1/4" – 3/8" |
Pre-Charge | Feet | 25 |
Max. Line Run | Feet | 50 |
Max. Elevation | Feet | 33 |
MCA | Amps | 10 |
MOCP | Amps | 15 |
Wire Size / # Wires | AWG16 / 4 |
Model | OS-12HP220V2TG | |
System Type | Heat Pump | |
Power Supply | 208-230V / 60Hz | |
Rated Current Cooling | Amps | 5.9 |
Rated Current Heating | Amps | 5.5 |
System Performance | ||
Cooling Capacity (Min-Max) | Btu/h | 12,000 |
Heating Capacity (Min-Max) | Btu/h | 12,000 |
SEER/EER | 15 / 9.0 | |
HSPF/COP | 8.2 / 3.0 | |
Indoor Unit | ||
Air Flow | CFM | 600/530/400 |
Sound Pressure Level – T/H/M/L | dB (A) | 39/35/31 |
Unit Dimension (WxHxD) | inches | 30.3 x 10.1 x 7.4 |
Package Dimension (WxHxD) | inches | 32.9 x 13.0 x 10.4 |
Net / Gross Weight | lb | 17 / 21 |
Outdoor Unit | ||
Compressor Type | DC Inverter-driven rotary | |
Sound Pressure Level | dB (A) | 57 |
Unit Dimension (WxHxD) | inches | 30.7 x 21.3 x 9.8 |
Package Dimension (WxHxD) | inches | 35.8 x 23.0 x 13.2 |
Net / Gross Weight | lb | 66 / 71 |
Refrigerant / Charge | oz. | R410A / 32.1 |
Line Set Size (Liquid – Suction) | inches | 1/4" – 3/8" |
Pre-Charge | Feet | 25 |
Max. Line Run | Feet | 82 |
Max. Elevation | Feet | 33 |
MCA | Amps | 10 |
MOCP | Amps | 15 |
Wire Size / # Wires | AWG16 / 4 |
Model | OS-18HP220V2TG | |
System Type | Heat Pump | |
Power Supply | 208-230V / 60Hz | |
Rated Current Cooling | Amps | 8.7 |
Rated Current Heating | Amps | 8.0 |
System Performance | ||
Cooling Capacity (Min-Max) | Btu/h | 18,000 |
Heating Capacity (Min-Max) | Btu/h | 18,000 |
SEER/EER | 15 / 9.0 | |
HSPF/COP | 8.2 / 3.0 | |
Indoor Unit | ||
Air Flow | CFM | 750/660/480 |
Sound Pressure Level – T/H/M/L | dB (A) | 42/39/31 |
Unit Dimension (WxHxD) | inches | 35.6 x 1 0.8 x 7.8 |
Package Dimension (WxHxD) | inches | 38.2 x 13.6 x 10.6 |
Net / Gross Weight | lb | 19 / 25 |
Outdoor Unit | ||
Compressor Type | DC Inverter-driven rotary | |
Sound Pressure Level | dB (A) | 59 |
Unit Dimension (WxHxD) | inches | 29.9 x 23.2 x 11.2 |
Package Dimension (WxHxD) | inches | 34.9 x 25.4 x 14.0 |
Net / Gross Weight | lb | 83 / 88 |
Refrigerant / Charge | oz. | R410A / 42.3 |
Line Set Size (Liquid – Suction) | inches | 1/4" – 1/2" |
Pre-Charge | Feet | 25 |
Max. Line Run | Feet | 98 |
Max. Elevation | Feet | 66 |
MCA | Amps | 14 |
MOCP | Amps | 20 |
Wire Size / # Wires | AWG16 / 4 |
Model | OS-24HP220V2TG | |
System Type | Heat Pump | |
Power Supply | 208-230V / 60Hz | |
Rated Current Cooling | Amps | 10.6 |
Rated Current Heating | Amps | 9.7 |
System Performance | ||
Cooling Capacity (Min-Max) | Btu/h | 22,000 |
Heating Capacity (Min-Max) | Btu/h | 22,000 |
SEER/EER | 15 / 9.0 | |
HSPF/COP | 8.2 / 3.0 | |
Indoor Unit | ||
Air Flow | CFM | 1250/1150/950 |
Sound Pressure Level – T/H/M/L | dB (A) | 49/43/39 |
Unit Dimension (WxHxD) | inches | 40.6 x 12.4 x 8.6 |
Package Dimension (WxHxD) | inches | 43.9 x 15.6 x 11.8 |
Net / Gross Weight | lb | 27 / 33 |
Outdoor Unit | ||
Compressor Type | DC Inverter-driven twin-rotary | |
Sound Pressure Level | dB (A) | 60 |
Unit Dimension (WxHxD) | inches | 33.3 x 27.6 x 12.6 |
Package Dimension (WxHxD) | inches | 38.0 x 29.7 x 15.6 |
Net / Gross Weight | lb | 104 / 111 |
Refrigerant / Charge | oz. | R410A / 56.4 |
Line Set Size (Liquid – Suction) | inches | 3/8" – 5/8" |
Pre-Charge | Feet | 25 |
Max. Line Run | Feet | 98 |
Max. Elevation | Feet | 66 |
MCA | Amps | 16 |
MOCP | Amps | 25 |
Wire Size / # Wires | AWG16 / 4 |