Leader Series



Leader Series:

  • “Enigma Lights” Display
    The hidden display is built into the front panel and isn’t visible when it’s off, it does not emit light at night and does not create any discomfort;
  • R410a – ECO Security
    R410a protects the ozone layer. It is more environment-friendly and energy-saving, opening a new idea of environmental protection. OLMO air conditioner deploys R410a to cause lest harms to the environment;
  • Smart Defrost
    The automatic defrost is available. After the defrosting is completed, it will automatically reverse to the heating operation; accordingly, it can not only fully ensure the heating effect of the air conditioner but also show a more durable effect;
  • Magic Sleep
    This function is developed specialy for you to have a sweetly sleep, without suffering from under-cooling or over-heating experience at night;
  • Top class Copper Pipe
    A copper pipe has new optimized and trapezoidal internal thread. The heat exchange area is increased, the heat exchange efficiency is improved, and the refrigerant (heating) efficiency is enhanced.
  • PFC Technology
    The adoption of highly efficient PFC technology makes OLMO air conditioner more economic on energy consumption;
  • “Auto Rest” Function
    “Automatic power-off” will stop your air conditioner after operating 10h. So, it’ll save energy and protect the environment;
  • Powerful Cooling & Heating
    Equipped with compressors and motors made by famous manufacturers, it is able to bring you a cool experience at the quickest time.
  • “Quiet Action”Function
    Both the indoor and outdoor units are designed with a consummate operating mechanism, which minimizes their noise, so it allows you to enjoy a cooled-down living space, despite of the sizzling heat outside;
  • “Dry Air” Function
    The independent dehumidifying function is able to keep your clothes dry even if the weather gets humid, thus freeing you from worries;
  • “Stop-cold” Function
    In heating mode, the fan speed is controlled, according to the evaporator temperature. Only when the evaporator is warm enough, the cross fan begins to run, preventing any cold blasting;
  • “Clean Inside” Function
    After shutting off, the cross fan still runs 3 additional minutes, therefore. Humidification in the indoor unit will be dried. There is no chance to mildew;
  • “Сlever Timer” Function
    It is equipped with the 24h/12h timing on/off fuction;
  • “Pipe Twins” Design
    Dual-direction Drainage Pipe Design.The fine design makes our products suit different styles of home environment, practical and easy for use;
  • “Auto-Guard” Protection
    With auto-protection, errors will be detected by the PCB and displayed by LED by the indoor unit. Protection will be taken;
  • Auto Restart “Reload”
    After being turned off or in case of an accidental power cut, Olmo air-conditioners are able to retain and restore the temperature and other settings, until being turned on or the power supply is resumed;
  • “Wonder Service” for Filter Mesh
    The Filter Mesh can easily be dismantled and cleaned. It guarantees a healthy indoor environment;
  • “SIX-layer” anti-rust protection
    The considerately-devised 6 layer anti-rusting technology, enables the outdoor unit to suffer rusting, and appear clean for long years.
Model   OSH-07AH5D
Perfomance Cool kW 2,05
Heat kW 2,20
Power supply     220-240V/50Hz/1F (indoor unit)
Nominal power consumption Cool/Heat kW 0,635/0,61
Energy efficiency EER (Cool) kW/kW 3,23
C.O.P. (Heat) kW/kW 3,61
The Air performance   m3/h 400
Noise level indoor unit dB(A) 27/29/31
outdoor unit dB(A) 50
Refrigerant     R-410A
Dimensions (width/height/depth) indoor unit mm 718Х240Х180
outdoor unit mm 600Х500Х232
Weight indoor unit kg 7
outdoor unit kg 21
Draining   l/h 0,80
Operating temperature range   °C -7/43
The weight of the refrigerant   kg 0,45
Liquid highway diameter   mm/inch 6,38/1/4"
Gas highway diameter   mm/inch 9,53/3/8"
Maximum height discontinuity highway   m 5
Maximum length highway   m 15
Model   OSH-09AH5D
Perfomance Cool kW 2,64
Heat kW 2,78
Power supply     220-240V/50Hz/1F (indoor unit)
Nominal power consumption Cool/Heat kW 0,815/0,77
Energy efficiency EER (Cool) kW/kW 3,24
C.O.P. (Heat) kW/kW 3,61
The Air performance   m3/h 430
Noise level indoor unit dB(A) 29/31/33
outdoor unit dB(A) 50
Refrigerant     R-410A
Dimensions (width/height/depth) indoor unit mm 718Х240Х180
outdoor unit mm 600Х500Х232
Weight indoor unit kg 7
outdoor unit kg 25
Draining   l/h 0,80
Operating temperature range   °C -7/43
The weight of the refrigerant   kg 0,51
Liquid highway diameter   mm/inch 6,38/1/4"
Gas highway diameter   mm/inch 9,53/3/8"
Maximum height discontinuity highway   m 5
Maximum length highway   m 15
Model   OSH-12AH5D
Perfomance Cool kW 3,52
Heat kW 3,66
Power supply     220-240V/50Hz/1F (indoor unit)
Nominal power consumption Cool/Heat kW 1,095/1,01
Energy efficiency EER (Cool) kW/kW 3,21
C.O.P. (Heat) kW/kW 3,62
The Air performance   m3/h 530
Noise level indoor unit dB(A) 29/33/35
outdoor unit dB(A) 50
Refrigerant     R-410A
Dimensions (width/height/depth) indoor unit mm 770Х240Х180
outdoor unit mm 700Х552Х256
Weight indoor unit kg 8
outdoor unit kg 30
Draining   l/h 1,20
Operating temperature range   °C -7/43
The weight of the refrigerant   kg 0,63
Liquid highway diameter   mm/inch 6,38/1/4"
Gas highway diameter   mm/inch 9,53/3/8"
Maximum height discontinuity highway   m 5
Maximum length highway   m 15
Model   OSH-18AH5D
Perfomance Cool kW 5,28
Heat kW 5,42
Power supply     220-240V/50Hz/1F (indoor unit)
Nominal power consumption Cool/Heat kW 1,64/1,50
Energy efficiency EER (Cool) kW/kW 3,22
C.O.P. (Heat) kW/kW 3,61
The Air performance   m3/h 760
Noise level indoor unit dB(A) 32/35/39
outdoor unit dB(A) 52
Refrigerant     R-410A
Dimensions (width/height/depth) indoor unit mm 900Х280Х202
outdoor unit mm 760Х552Х256
Weight indoor unit kg 11
outdoor unit kg 36
Draining   l/h 2,80
Operating temperature range   °C -7/43
The weight of the refrigerant   kg 0,98
Liquid highway diameter   mm/inch 6,38/1/4"
Gas highway diameter   mm/inch 12,7/1/2"
Maximum height discontinuity highway   m 5
Maximum length highway   m 15
Model   OSH-24AH5D
Perfomance Cool kW 7,03
Heat kW 7,18
Power supply     220-240V/50Hz/1F (outdoor unit)
Nominal power consumption Cool/Heat kW 2,18/1,99
Energy efficiency EER (Cool) kW/kW 3,22
C.O.P. (Heat) kW/kW 3,61
The Air performance   m3/h 760
Noise level indoor unit dB(A) 35/37/41
outdoor unit dB(A) 56
Refrigerant     R-410A
Dimensions (width/height/depth) indoor unit mm 900Х280Х202
outdoor unit mm 902Х650Х307
Weight indoor unit kg 11
outdoor unit kg 52
Draining   l/h 3,00
Operating temperature range   °C -7/43
The weight of the refrigerant   kg 1,38
Liquid highway diameter   mm/inch 9,53/3/8"
Gas highway diameter   mm/inch 15,8/5/8"
Maximum height discontinuity highway   m 5
Maximum length highway   m 15